General
- Standard HRSG (heat recovery steam generator/economizer) for installation behind gas turbines
- Vertical water tube boiler with forced circulation
- Sturdy design
- Compact design (small footprint)
- Easy service and inspection
- Fully drainable
- Fast response to load changes
- Fast start-up time
- Dry running at full load on gas turbine
Design data
| Gas turbine output: |
10 - 35 MW |
| Gas turbine fuel type: |
Natural gas, light oil |
| Exhaust gas flow: |
40 - 120 kg/s |
| Exhaust gas temperature: |
< 570ºC |
| Steam capacity: |
10 - 50 t/h |
| Operating steam pressure: |
10 - 35 bar |
| Steam temperature: |
Saturated - 450ºC |
Description
MISSION™ WHR-GT is the latest marine economizer developed by Aalborg Industries and is designed for installation behind a gas turbine.
Waste heat from the gas turbine exhaust gas is used for generating saturated or superheated steam.
The waste heat recovery boiler/economiser is of the forced circulation type. The economizer is fully constructed of high temperature resistant Chrome Molybdenum steel. |