Complete Solutions Marine
Marine Boiler Service
Products & Systems
References & Media
|
|
UNEX™ CHB
________________________________________________________________________________________
General
- Bare water tube, oil-fired boiler fuelled with diesel oil, heavy fuel or sludge/waste oil
- Low capacity types designed without refractory
- Provided with a stationary water washing cleaning system
- Supplied with rotary cup burner, steam atomising burner or pressure jet burner
Design Data
| Steam capacity: |
0.75 - 15 t/h |
| Design pressure |
10 - 16 bar(g) |
| Thermal output: |
up to 10 MW |
Description
The UNEX™ CHB boiler consists of a large furnace welded to vertical, plain-type convection tubes. The low-alloyed plate material is durable against cracking, and it is easy to weld.
CHB boilers with a steam capacity of up to 5 t/h have fully water-cooled furnaces. They are constructed without refractory.
The furnaces of boilers with larger capacities are welded using gas-tight membrane water tubes connected to the dome-shaped top of the furnace.
Adequate furnace dimensioning guarantees good combustion, moderate loading and low material stresses. With an efficiency level of approx. 85%, the CHB has an economical operation and offers savings in fuel costs.
Due to the standard built-in water washing device, the UNEX™ CHB boiler is easy to clean.
UNEX™ CHB can operate as a steam drum for an exhaust gas economiser. If the economiser capacity is high, the height of the boiler will be increased accordingly.
|
|
Capacity, Dimensions & Weight

| Type |
Steam |
Height A |
Diameter B |
Gas outlet |
Dry weight # |
Water volume |
|
kg/h
|
mm |
mm |
DN |
kg |
m3 |
CHB 750 |
750 |
2,945 |
1,400 |
200 |
3,250 |
1.5 |
CHB 1000 |
1,000 |
3,465 |
1,400 |
200 |
3,860 |
1.6 |
CHB 1500 |
1,500 |
3,560 |
1,600 |
250 |
5,100 |
2.1 |
CHB 2000 |
2,000 |
3,985 |
1,700 |
300 |
6,000 |
2.5 |
| CHB 2500 |
2,500 |
4,150 |
1,900 |
300 |
7,700 |
3.8 |
| CHB 3000 |
3,000 |
4,420 |
2,000 |
300 |
9,000 |
4.4 |
| CHB 4000 |
4,000 |
4,670 |
2,200 |
350 |
10,400 |
5.6 |
| CHB 5000 |
5,000 |
5,150 |
2,300 |
400 |
12,650 |
6.2 |
| CHB 6000 |
6,000 |
5,300 |
2,300 |
400 |
15,900 |
6.6 |
Membrane tube furnace |
| CHB 6000 |
6,000 |
5,680 |
2,500 |
400 |
16,100 |
6.3 |
| CHB 8000 |
8,000 |
5,920 |
2,700 |
500 |
17,000 |
6.7 |
| CHB 10000 |
10,000 |
6,760 |
2,800 |
500 |
25,300 |
8.4 |
| CHB 12000 |
12,000 |
7,180 |
3,000 |
600 |
26,500 |
10.0 |
| CHB 15000 |
15,000 |
7,800 |
3,000 |
700 |
27,500 |
10.5 |
# Dry weight including insulation, valves and fittings, and burner.
DATA SHEET series
© Aalborg Industries 2001, rev.: 1.0, June 2005 (Design data are subject to change without prior notice).